Hb Testing System-Mission® Ultra for Accurate Measurement
Introduction
Direct Measurement of Hemoglobin (Hb) and Hematocrit (Hct).
Main Features
【Quick】
- Hb and Hct results in <12 seconds
- Direct sampling with only 4 μL of capillary or venous whole blood
- Simply insert strip, apply specimen and read results
【Accurate】
- Results equivalent to automatic hematology analyzers
- Wide Hb measurement range of 0-26 g/dL with Hct range of 0-75%
- Both Hb and Hct are measured, not calculated
【Convenient】
- Designed for point of care testing
- No specimen preparation required
- Strip ejector to avoid contact with used test strips
- Battery operated for portability
- Memory stores up to 500 results
Main Performance
- Detection Principle: Electrochemical
- Time to Results: <12 seconds
- Specimen Volume: 4 μL
- Specimen Type: Capillary or venous whole blood (EDTA-K2 & EDTA-K3)
- Memory: 500 tests with date/time
- Hb Measurement Range: 0-26 g/dL (0-16.1 mmol/L)
- Hct Range: 0-75 %
- PC Interface: Audio to RS232
- Calibration: Automatic
- Hb Total Precision: Hb 0-10 g/dL: SD≤0.4 g/dL; Hb 10.1-26 g/dL: CV≤4%
- Accuracy: Hb 0-10 g/dL: ±0.7 g/dL; Hb 10.1-26 g/dL: ±7%
- Operating Conditions: 10-40 °C (50-104 °F); 10-90% RH
- Meter Storage Conditions: 0-50 °C (32-122 °F); 10-90% RH
- Strip Storage Conditions: 2-30 °C (35.6-86 °F); 10-90% RH
- Strip Shelf Life: 24 months
- Power Source: 3V CR2032 Li
- Battery Life: ≥ 1000 tests
- Automatic Shut Off: 4 mins
Packaging & Delivery
Meter Dimensions (L x W x H): 90 x 58 x 20 mm
LCD Dimensions (L x W): 36 x 41 mm
Weight (without batteries): 64 g
Accessories:
1*Meter
1*Warranty Card
10*Lanoets (26G)
10*Test Strips
1*User Manual
1*Lancing Device
1*Carrying Case
1*Code Chip
1*Quick Reference Guide
1*Test Strip Insert
1*Lancing Device Insert
2*3V CR2032 Li Batteries
Frequently Asked Questions
1. Can institutional buyers obtain both Hb and Hct measurements without purchasing two separate testing systems?
Yes. Mission® Ultra directly measures both hemoglobin (Hb) and hematocrit (Hct) using a single device. Its measurement ranges are 0–26 g/dL for Hb and 0–75% for Hct. For institutional procurement projects requiring both parameters, this combined functionality simplifies equipment selection, purchasing configurations, and inventory management without requiring separate instruments for each measurement.
2. Can bulk buyers supply the same meter model for procurement projects requiring different blood sample types?
Yes. Mission® Ultra supports capillary whole blood and venous whole blood collected with EDTA-K2 or EDTA-K3 anticoagulants. Both sample types require only 4 μL of blood. This allows bulk buyers to supply one meter model across purchasing projects with different blood collection requirements, reducing the need to maintain separate product models. The specified sample compatibility does not include serum or plasma.
3. Why should bulk buyers avoid listing a uniform ±7% accuracy specification for this Hb meter?
Mission® Ultra uses different accuracy limits across its Hb measurement ranges. Accuracy is specified as ±0.7 g/dL from 0–10 g/dL and ±7% from 10.1–26 g/dL. The corresponding precision specifications are SD ≤0.4 g/dL and CV ≤4%, respectively. Bulk buyers preparing technical comparison sheets, tender submissions, or product specifications should retain these range-specific figures to ensure accurate comparisons with competing hemoglobin testing systems.
4. What features make Mission® Ultra suitable for procurement projects requiring rapid Hb and Hct testing equipment?
Mission® Ultra requires only 4 μL of whole blood and provides Hb and Hct readings in under 12 seconds without separate sample preparation. The meter also features a test strip ejector for convenient strip removal. For buyers sourcing portable testing equipment in larger quantities, these integrated features simplify the equipment configuration without requiring additional blood transfer or sample preparation devices.
5. What data storage and connectivity options are available for institutional purchasing projects?
Mission® Ultra stores up to 500 test records with date and time information and features an Audio-to-RS232 PC interface. Bulk buyers can specify these capabilities when preparing equipment configurations for institutional customers requiring electronic record management. Since this interface differs from standard USB and Bluetooth connections, compatible accessories should be selected according to the stated RS232 connection requirements.
6. How should bulk buyers plan test strip quantities for recurring orders beyond the initial meter kits?
Each Mission® Ultra standard kit includes 10 test strips, 10 lancets, a lancing device, and a code chip. These starter quantities are separate from the consumables required for ongoing supply contracts. Bulk buyers should plan meter orders and replacement strip quantities independently based on purchasing volumes. The strips have a listed shelf life of 24 months and require storage at 2–30°C, providing clear specifications for inventory rotation and replenishment planning.
Delivery date : 30-45 days
Logo/Color: Customizable
Documents: Health Bureau documentation complete.
More than just a product — a reliable partner for your healthcare business.
- Request wholesale pricing*Become a distributor*OEM inquiry
- Request wholesale pricing*Become a distributor*OEM inquiry
- Request wholesale pricing*Become a distributor*OEM inquiry
- Request wholesale pricing*Become a distributor*OEM inquiry
- Request wholesale pricing*Become a distributor*OEM inquiry